现在位置首页>行业专用>动物实验>动物心血管系统>现货,140101EZ – Working Heart Porcine,140101EZ-工作心脏猪
现货,140101EZ – Working Heart Porcine,140101EZ-工作心脏猪
现货,140101EZ – Working Heart Porcine,140101EZ-工作心脏猪
  1. 现货,140101EZ – Working Heart Porcine,140101EZ-工作心脏猪

现货,140101EZ – Working Heart Porcine,140101EZ-工作心脏猪

产品报价:询价 更新时间:2018/6/15 17:10:34 地:其他国家 牌:radnoti 号: 140101EZ 厂商性质: 生产型,贸易型,服务型, 公司名称: 世联博研(北京)科技有限公司 产品关键词: 工作心脏猪   Working Heart Porcine   140101EZ   Radnoti   现货  
202
访问人数
0
累计评论


王荣 : (18618101725) (18611717737,18618101725) (联系我时,请说明是在齐乐娱乐上看到的,谢谢!)

该厂商其他产品

我也要出现在这里
  1. 现货,130101EZ – Working Heart Mouse,工作心脏小鼠
    ¥询价 现货,130101EZ – Working Heart Mouse,工作心脏小鼠 世联博研(北京)科技有限公司
  2. 现货,140101EZ – Working Heart Porcine,140101EZ-工作心脏猪
    ¥询价 现货,140101EZ – Working Heart Porcine,140101EZ-工作心脏猪 世联博研(北京)科技有限公司
  3. 现货,Super Heart System,超级心脏系统
    ¥询价 现货,Super Heart System,超级心脏系统 世联博研(北京)科技有限公司
  4. 现货120101BEZ – Working Heart Rat/Guinea Pig/Rabbit,工作心率/豚鼠/兔子
    ¥询价 现货120101BEZ – Working Heart Rat/Guinea Pig/Rabbit,工作心率/豚鼠/兔子 世联博研(北京)科技有限公司
  5. vascularsimulations心脏周期血流量复制仪器装置系统,Vascular Simulations Replicator
    ¥询价 vascularsimulations心脏周期血流量复制仪器装置系统,Vascular Simulations Replicator 世联博研(北京)科技有限公司

140101EZ – Working Heart Porcine

The isolated perfused heart system, as originated by Oscar Langendorff nearly a century ago has become a mainstay of pharmacological and physiological research.  The system allows the examination of cardiac inotropic, chronotropic and vascular effects without the complications of an intact animal model.  The original design has evolved to encompass both constant pressure and constant flow models in both recirculating and non-recirculating modes, as well as Working Heart mode.  The Radnoti perfused heart systems has the capacity to function in any of these configurations, allowing the researcher to have maximal flexibility in experimental design.Overview of #140101 Working Heart SystemThis version of the working heart system uses a peristaltic pump to generate the hydrostatic head for the constant pressure Langendorff preparation that initially sustains the heart. Perfusate is drawn from the High Volume 5-liter water jacketed reservoir, routed through the atrial bubble trap and diverted up to the aortic bubble trap at the atrial cannula. After the heart has stabilized, the researcher changes the direction of flow via a set of tubing clamps at “Y” connectors acting as a 3-way valve at the atrial cannula to switch from retrograde to working heart mode by directing perfusate into the left atria under hydrostatic pressure (5 mm Hg nominal, adjustable). The perfusate then enters the left ventricle and is pumped by the heart against an adjustable pressure head set by the researcher. After load may be adjusted on the aortic line to vary resistance by incorporating the supplied compliance loop on the aortic side during working heart mode. Buffer may be directed to waste following the compliance loop or directed to the 140144 Large Volume Sheet Flow Oxygenating chamber for re-gassing and returned to the heart. At this point the main 5-liter High Flow buffer reservoir supply may be omitted from the circuit and a nominal fixed volume (set by the researcher) re-circulated through the system.
  1. Supports Isolated Working Heart Mode (Neely)
  2. #140101BEZ is suitable for large hearts including porcine.
  3. Supports all Langendorff Modes in addition to Working Heart
  4. Atrial compliance loop: simulates physiological preload
  5. After load compliance loop: simulates physiological after load and mimics normal vascular elasticity.
  6. Independently adjustable preload and after load pressure
  7. Preparations may be spontaneously beating or paced using Radnoti #140157 Pacing Electrode
  8. Superb temperature control due to our water-jacketed heart chamber, components and water-jacketed key perfusate line tubing. Start-up to 37°C in 15 mins with less than 0.01° C error.
  9. Quick and easy disassembly due to our quick-disconnect tubing.
  10. Easy system maintenance and long-term durability due to GLP-compliant open architecture and no moving/active parts on compliance loops.
  11. Easy cleaning: our crystal clear borosilicate glassware is fully autoclavable and unlike plastic systems, are not affected by agents and proteins.
  12. Easy replacement: Individual components allow for easy replacement in the event of breakage and can be replaced without factory return.
  13. Customized configurations available. As with all Radnoti systems, the modular design allows for extreme flexibility and system reconfigurations.
  14. Due to the large scale of the apparatus and the donor heart, instrumentation is easily accommodated.
The system can be instrumented to measure:
  1. LVP
  2. Perfusate Flow
  3. Ejection Flow
  4. Perfusate Pressure
  5. Cardiac Output
  6. ECG
  7. Optical Imaging
  8. Luminescence
  9. Fluorescence
  10. Apical Force
  11. Ions
  12. Metabolism
  13. Cardiac Pacing
Recommended ReadingIf the experimenter is not conversant with cardiovascular pharmacology and physiology, there are a number of excellent texts that will introduce this area to you.  Besides the medical physiology and pharmacology standards, there are a number of specialized texts.  Pharmacologic Analysis of Drug-receptor Interaction  by Terrence P. Kenakin (Raven Press, ny, 1987) is a compact text with practical emphasis on isolated tissues and organs in pharmacological research.